After increasing length of DES Data Type to 250 and Validating. After I close X3 and re-open I cannot get into any function. I receive these errors: Function not defined for the value given
The correct syntax for the selection criteria for a Sage X3 date field is: [DD/MM/YYYY]
Classified as follows "DD=Day", "MM=Month" and "YYYY=Year"
Example :
Criteria using CREDAT in table for records with a CREDAT less than March 12th, 2020. …
Cause :
There is failure to communicate with MSSQL server.
Fix
1. Ensure SQL services are running
2. Ensure the servers can communicate if the system a multi tier.
3. Check firewall settings
Cause:
There are various possibilities including a corrupt ACLASSE table or an outstanding folder validation
Fix.
1. Try to validate the ACLASSE table through Development > Data and Parameters > tables
2. Test
if the above fix fails, perform…